Internal PI controller |
Top Previous Next |
|
The EA09's firmware implements four PID controllers for Robotino's three drive motors and the optional fourth motor. The PID controller equation is:
The PID controller's parameters are:
Kp Ki = 1/Tn Kd
The firmware implements the controller in integer arithmetic. The values kp , ki and ki are integer values in the range [0;255]. From these values we calculate Kp , Ki and Kd Kp= kp / 2 Ki= ki / 1024 Kd= kd / 2
From the Telnet user interface you are setting kp , ki and kd.
The maximum Kp is 255 / 2 = 127,5. The maximum Ki is 255 / 1024 =0,249. The maximum reset time Tnmaxis 1024ms because Ki=0 disables the I-control part. Tnmax is a theoretical value. The integral over the deviations from the speed set-point e(t) is computed over the previous 64ms only. The maximum Kd is 255 / 2 = 127,5
Default values programmed into the firmware are: kp = 25 ki = 25 kd = 25
|